Produkt Foardielen
Wêrom dit 241kWh kabinet BESS opfalt
Grade A LiFePO4 · 314Ah
1P240S single-string - gjin parallelle ûnbalâns. 100% fabryk-screened Minder as of gelyk oan 3mV ôfwiking neffens IEC 62620.
Liquid / Air Cooling ynstelbere
Glycol cold plates for >Omjouwings fan 40 graden: ± 2 graden seluniformiteit, 15–20% langer sykluslibben tsjin lucht -kuolle yn waarme regio's.
Alles-yn-Modulêre yntegreare
Batterij + PCS + BMS + EMS + STS + koeling + fjoer ûnderdrukking yn ien IP55 iepenloftspul. Nul op-site gearstalling.
5-Layer Safety Architecture
Cell BMS → module fuse → rack termyske barriêre → kabinet brân ûnderdrukking → systeem emergency disconnect. Elk ûnôfhinklik.
Grutter as of lyk oan 89% DC Round-Triiseffisjinsje
IGBT-based PCS. AC-AC ≥86%. Liquid-cooled maintains 1–2% higher efficiency in >40 graden omjouwings.
Cloud EMS + O&M op ôfstân
Echte-tiid SOC/SOH/power/temperatuer dashboards. Anomaly warskôgings. OTA firmware updates. API foar SCADA-yntegraasje.
Systeem Arsjitektuer
Binnen it yntegreare kabinet BESS
Seis subsystemen, ien omwâling. Gjin eksterne oerienkomst nedich.
125KW Bi-PCS
Grid-tied + off-rastermodi. STS Minder as of gelyk oan 20ms oerdracht. 380V/400V/415V 3-faze, 50/60Hz.
Energy Management System (EMS)
Peak sharing, TOU arbitrage, sinne sels-konsumpsje, fraachantwurd. SCADA API.
Battery Management System (BMS)
V/I/T-monitoring op sel-nivo. Aktive balâns oer 240S string. SOC / SOH ± 2% krektens.
Static Transfer Switch (STS)
Sub-20ms grid↔off-grid. UPS-kontinuïteit foar krityske lading.
Thermal Management & Cooling
Lucht: IP55 twongen fentilaasje. Liquid: glycol kâlde platen, ± 2 graad uniformiteit.
Fire Suppression System
Smoke / gas detect → aerosol rapid → perfluorohexanone oerstreaming. Nul residu.
241kWh Kabinet BESS Spesifikaasje
BatterijParameter
| Model | CBS240 | |
| Rated Voltage | 768V | |
| Rated Kapasiteit | 314 Ah | |
| Enerzjy | 241 kWh | |
| Operating Voltage Range | 624-864V | |
| Series en parallelle ferbining | 1P240S | |
Systeem parameter
| Grid Standert | 3L+N+PE |
| Rated Power | 125 kW |
| Grid Voltage Range | 380V (-15% oant +10%) |
| Rated Aktueel | 190A |
| Maksimum konverzje effisjinsje | 97% |
| Oer-laden Mooglikheid | 110% 1 min |
| Rated Frequency | 50Hz |
| Grid Frequency Range | 50 Hz ± 2,5 Hz |
| Grid Total Distortion Rate (THDi) | Minder as of gelyk oan 3% by folsleine lading |
| Trije-faze ûnbalânsgraad | 100% |
| Power Factor | -1~+1 oanpasber |
Algemiene parameter
| Koelsysteem | Liquid koeling (loftkoeling opsjoneel) |
| Fire Extinguishing System | Perfluorhexanone + aerosol dual-faze |
| Operating Temperatuer | -20 ~ 50 graden |
| Lûd | Minder as of gelyk oan 60dB |
| IP-klasse | IP54 |
| Grutte (B × D × H) | 1195 × 1400 × 2140 mm (47.1 × 55.1 × 84.3 yn) |
| Gewicht | Minder as of gelyk oan 2,8 ton |
Noat:Standert betingsten. Koeling, inverter, sertifikaten konfigurearber per projekt.Download folsleine datasheet (PDF)
De kabinet BESS wurde offisjeel fermeld as kompatibel troch ferskate wrâldwiid erkende fabrikanten fan inverter. Elk produkt hat strange testen en falidaasje ûndergien om naadleaze kommunikaasje, betroubere operaasje en folsleine kompatibiliteit te garandearjen oer ferskate ynverterplatfoarms.












Certifications

241kWh Kabinet BESS - Technyske FAQ
F: Wêrom brûkt de 241kWh 1P240S ynstee fan parallelle snaren, en wat is de echte -wrâldimpact?
A: 1P240S set 240 sellen yn searje mei nul parallelle snaren. Dit elimineert inter-stream-ûnbalâns - in mienskiplike oarsaak fan foartiid ferfal fan kapasiteit yn multi-parallelle ûntwerpen. Mei mar ien snaar beheart de BMS in ienfâldiger, mear foarsisber lading- / ûntlaadprofyl. De hannel -ôf: elke 314Ah-sel moat in strakkere ynkommende screening passe (Minder as of gelyk oan 3mV, Minder as of lyk oan 5mΩ) om swakke-linkdegradaasje te foarkommen. Yn 'e praktyk betsjut dit mear konsekwint sykluslibben oer de folsleine 241,15 kWh - brûkers sjogge minder SOH-diverginsje tusken jierren 3 en 10 yn ferliking mei 2P- of 4P-arsjitektueren fan ferlykbere totale kapasiteit.
F: As in sel yn dit kabinet yn termyske rinnen giet, wat hâldt it dan fan it berikken fan neistlizzende modules?
A: Fiif lagen fjoer sequentially: sel BMS flagge de anomaly yn<500ms and isolates it; module fuses cut fault current before propagation; rack-level ceramic barriers block heat transfer physically; if temperature or gas levels still rise, the cabinet's perfluorohexanone + aerosol system floods the compartment automatically (no residue, no electronic damage); and finally the STS disconnects the entire cabinet from the grid in ≤20ms. Because this is LiFePO4 - not NCM or NCA - the failing cell does not release oxygen, which is the main propagation driver in ternary chemistries. No layer depends on another to function. For a deeper look at how UL testing validates these safety layers, see our guide on BESS UL-sertifikaasje.
Q: 241kWh nominaal, mar hoefolle AC enerzjy eins komt út per folsleine syklus?
A: At default EMS settings (5% bottom SOC reserve, 2% top), usable DC capacity is ~224 kWh per cycle. Multiply by ≥86% AC-AC round-trip efficiency (at 25°C, 0.5C) and you get roughly 193–207 kWh AC delivered to load - the range depends on ambient temperature and C-rate. In hot climates (>40 graden), leveret de floeistof-gekoelde fariant 1–2% hegere effisjinsje as loft-kuolle, om't strakkere termyske kontrôle de ynterne wjerstân ferminderet. As jo projekt maksimale útfier fereasket, binne de EMS SOC-reserves ferstelber - mar smellere reserves hannelje langstme foar koarte-kapasiteit.
F: Dit kabinet weaget Minder as of gelyk oan 2,8 ton - wat hat de side nedich om it te stypjen?
A: Stifting: nivo betonnen pad of stielen frame rated grutter as of gelyk oan 4.000 kg. De ienheid (1400 × 1300 × 2387 mm) hat 800 mm klaring nedich foar tsjinst tagong en 300 mm oan oare kanten foar fentilaasje. In standert Grutter as of lyk oan 3.5t heftruck kin dizze - gjin kraan pleatse. Elektrysk: 3-faze 380/400/415V AC-ferbining, lokale koade-grûning, Ethernet- as RS485-kabel foar EMS. Polinovel ferstjoert dimensjeare stiftingstekeningen en kabelrouting-gidsen mei elke bestelling, en biedt fergese stipe foar ynstjoering op ôfstân fia fideoproppen.
F: As ik 4–8 fan dizze 241kWh kasten parallel meitsje, hoe foarkomt de EMS unjildich ferâldering?
A: The centralized EMS runs a weighted SOC balancing algorithm each control cycle (~100ms): cabinets with higher SOC discharge proportionally more, lower-SOC units receive more charge current. This keeps all cabinets within a tight SOC band and prevents any single unit from cycling disproportionately - which is the main cause of uneven aging in parallel BESS systems. Each cabinet retains independent BMS and PCS, so if one trips on a fault, the others absorb its load seamlessly. Communication: Modbus-TCP over Ethernet, 1-second polling. For systems >2 MWh, advisearret Polinovelcontainerized BESSfoar bettere $ / kWh op skaal.
F: Kin de 125KW PCS oerdeis mei raster-bûn piekskeerwurk en nachts-grid-backup yn deselde ynstallaasje behannelje?
A: Ja - it EMS stipet tiid-plande modus wikseljen. Foarbyld: grid-tied TOU arbitrage 6AM–10PM, automatyske off-grid backup 10PM–6AM. De STS behannelet elke oergong yn Minder as of gelyk oan 20ms. Foar opsetten wêrby't guon loads grid-moatte wurde, wylst oaren tagelyk fan -grid rinne (split-bus), is ekstra skeakelwurk nedich bûten de standertkonfiguraasje.Nim kontakt op mei Polinovel engineeringfoar split-busprojekt scoping en prizen.
Technyske ynsjoch foar C&I Energy Storage

Hoefolle kostet in BESS wirklik yn 2025?
Turnkey prizen, ferburgen kosten, en ROI-metodology foar kabinet- en kontenerprojekten.

Grutteskalige enerzjyopslach - Wat is feroare?
Duration trade-offs, produksjebeperkingen, en wêrom EMS-software wichtiger is dan minsken tinke.

Wannear te skaaljen fan kabinet nei kontener BESS
Kapasiteit drompels, kosten breakpoints, en foarm faktor beslút ramt.
heale ferkeap...: 125kw 241kwh outdoor kabinet enerzjy opslach systeem, Sina 125kw 241kwh outdoor kabinet enerzjy opslach systeem fabrikanten, leveransiers, fabryk